A compact microstrip six-port reflectometer (SPR) with extended bandwidth is proposed in this paper. The design is based on using 16-dB multi-section coupled line directional couplers and a multi-section 3-dB Wilkinson power divider operating from 1 to 6 GHz. The proposed SPR employs only two calibration standards: a matched load and an open load. As compared to other dielectric substrates, fabricating the proposed SPR involves using a low-cost (FR4) substrate. A novel algorithm is also proposed to estimate the complex reflection coefficient over the frequency ranges at which the standard performance of the circuit components is not fully satisfied. The new algorithm is based on the circles’ intersection points, which have been de
... Show MoreBall and Plate (B&P) system is a benchmark system in the control engineering field that has been used to verify many control methods. In this paper the design of a sliding mode . controller has been investigated and verified in real-time via implementation on a real ball and plate system hardware. The mathematical model has been derived and the necessary parameters have been measured. The sliding mode controller has been designed based on the obtained mathematical model. The resulting controller has been implemented using the Arduino Mega 2560 and a ball and plate system built completely from scratch. The Arduino has been programmed by the Arduino support target for Simulink. Three test signals has been used for verification purposes
... Show MoreThin films Tin sulfide SnS pure and doped with different ratios of Cu (X=0, 0.01, 0.03 and 0.05) were prepared using thermal evaporation with a vacuum of 4*10-6mbar on two types of substrates n-type Si and glass with (500) nm thickness for solar cell application. X-ray diffraction and AFM analysis were carried out to explain the influence of Cu ratio dopant on structural and morphological properties respectively. SnS phase appeared forming orthorhombic structure with preferred orientation (111), increase the crystallinity degree and surface roughness with increase Cu ratio. UV/Visible measurement revealed the decrease in energy gap from 1.9eV for pure SnS to 1.5 for SnS: Cu (0.05) making these samples suitable f
... Show MoreAbstract
The present paper attempts to detect the level of (COVID-19) pandemic panic attacks among university students, according to gender and stage variables.
To achieve this objective, the present paper adopts the scale set up by (Fathallah et al., 2021), which has been applied electronically to a previous cross-cultural sample consisting of (2285) participants from Arab countries, including Iraq. The scale includes, in its final form, (69) optional items distributed on (6) dimensions: physical symptoms (13) items, psychological and emotional symptoms (12) items, cognitive and mental symptoms (11) items, social symptoms (8) items, general symptoms (13) items and daily living practices (12) items
... Show MoreAbstract:
The distribution or retention of profits is the third decision among financial management decisions in terms of priority, whether at the level of theory or practice, as the issue of distribution or retention is multi-party in terms of influence and impact, as determining the optimal percentage for each component is still the subject of intellectual debate because these decisions are linked to the future of the organization and several considerations, The research focus on the nature of the policies followed by the Iraqi banking sector As the sample chosen by the intentional sampling method was represented by the Commercial Bank of
... Show MoreBackground: Spleen is a hemopoietic organ which is capable of supporting elements of different systems. It is affected by several groups of diseases; inflammatory, hematopoietic, reticuloendothelial proliferation, portal hypertension and storage diseases. Ultrasound (US) may detect mild splenomegaly before it is clinically palpable. Knowledge of the normal range of spleen size in the population being examined is a prerequisite. Racial differences in splenic length could result in incorrect interpretation of splenic measurements and such differences would make it difficult to standardize expected splenic length and to determine non- palpable splenic enlargement.Objectives: To measure the normal values of splenic lengthin Iraqi subjects an
... Show More