Preferred Language
Articles
/
-hc38pEBVTCNdQwCJZz3
Improvement the corrosion Behavior of Titanium by Nanotubular Oxide in a simulated saliva solution
...Show More Authors
Abstract<p>The corrosion behavior of Titanium in a simulated saliva solution was improved by Nanotubular Oxide via electrochemical anodizing treatment using three electrodes cell potentiostat at 37°C. The anodization treatment was achieved in a non-aqueous electrolyte with the following composition: 200mL ethylene glycol containing 0.6g NH4F and 10 ml of deionized water and using different applied directed voltage at 10°C and constant time of anodizing (15 min.). The anodized titanium layer was examined using SEM, and AFM technique.</p><p>The results showed that increasing applied voltage resulted in formation titanium oxide nanotubes with higher corrosion resistance (more positive value of the corrosion potential). The results revealed that good adhered well-ordered vertically aligned titania nanotubes with inner tube diameter of 82nm an mean length of 3microns could be obtained at 30VDC. Low corrosion current density (579 nA.cm-2) and corrosion potential equal to (-209 mV) were observed for untreated titanium metal while a dramatic fall down of the corrosion current was observed for nanotubes TiO2 (76 nA.cm-2) and more positive value of corrosion potential (-138 mV) was observed revealing good corrosion resistance of the improved titanium in saliva solutions.</p>
Scopus Crossref
View Publication
Publication Date
Sun Dec 30 2001
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Isolation Behavior of Metal Modified Novolac Resin
...Show More Authors

View Publication Preview PDF
Publication Date
Sat Apr 07 2018
Journal Name
Civil Engineering Journal
Behavior of Precast Prestressed Concrete Segmental Beams
...Show More Authors

The structural behavior of Segmental Precast Post-tensioned Reinforced Concrete (SPPRC) beams largely depends on the behavior of the joints that connect between the segments. In this research, series of static tests were carried out to investigate the behavior of full-scale SPPRC beams with different types of epoxy-glued joint configurations; multi-key joint, single key, and plain key joint. The reference specimen was monolithically casted beam and the other specimens were segmental beams with five segments for each one. The general theme from the experimental results reflects an approximate similarity in the behavior of the four beams with slight differences. Due to the high tensile strength of the used epoxy in comparison to concr

... Show More
Crossref (10)
Clarivate Crossref
Publication Date
Sun Dec 06 2009
Journal Name
Baghdad Science Journal
Titania Effect on Sintering behavior of Alumina
...Show More Authors

The sintering behavior of Alumina was investigated by adding TiO2. The addition of TiO2 lowered the sintering temperature of the Alumina compared with those of pure Alumina. The result suggests that TiO2 acts as an activator for sintering of Alumina. Water absorption, apparent porosity and density were examined for both pure and TiO2 added to Alumina samples. The variations of sintering behavior were discussed in terms of shrinkage, porosity, water absorption and density. Thermal shock resistance was also examined. In term of this work, the way of improving the thermal shock resistance in oxide- based materials by adding reactive Titania powder to the Alumina samples. The laboratory results showed an improvement in thermal shock resistance

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Sep 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Studying Thermal Cracking Behavior of Vacuum Residue
...Show More Authors

   In the oil industry, the processing of vacuum residue has an important economic and environmental benefit. This work aims to produce industrial petroleum coke with light fuel fractions (gasoline, kerosene , gas oil) as the main product and de asphalted oil (DAO) as a side production from treatment secondary product matter of vacuum residue. Vacuum residue was produced from the bottom of vacuum distillation unit of the crude oil. Experimentally, the study investigated the effect of the thermal conversion process on (vacuum residue) as a raw material at temperature reaches to 500 °C, pressure 20 atm. and residence time for about 3 hours. The first step of this treatment is constructing a carbon steel batch re

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Feb 01 2016
Journal Name
Journal Of Engineering
Fatigue Behavior of Modified Asphalt Concrete Pavement
...Show More Authors

Fatigue cracking is the most common distress in road pavement. It is mainly due to the increase in the number of load repetition of vehicles, particularly those with high axle loads, and to the environmental conditions. In this study, four-point bending beam fatigue testing has been used for control and modified mixture under various micro strain levels of (250 μƐ, 400 μƐ, and 750 μƐ) and 5HZ. The main objective of the study is to provide a comparative evaluation of pavement resistance to the phenomenon of fatigue cracking between modified asphalt concrete and conventional asphalt concrete mixes (under the influence of three percentage of Silica fumes 1%, 2%, 3% by the weight of asphalt content), and (chan

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 15 2023
Journal Name
Bionatura
Surface assessment of CNC laser treated commercially pure Titanium and Ti 13 Zr 13 Nb alloy
...Show More Authors

This study aimed to evaluate the surface changes of commercial pure Titanium disks (CP Ti) and the Ti 13Nb 13 Zr (Alloy) with a zigzag pattern of laser surface treatment. In vitro, experimental study of CNC Laser treatment on the CP Ti and Alloy disks. Texturing the surfaces of CP Ti and Alloy disks via CNC laser, the sample disks were analyzed using surface roughness, wettability and FESEM. The FESEM revealed a proper increase in the surface texturing and roughness on macro and micro measures without crack formation or dramatic change of the core substance of the CP Ti and Alloy disks. The CNC laser is an effective and suitable method for surface texturing CP Ti and Alloy for dental implantology. Keywords: Commercial pure Titanium;

... Show More
View Publication Preview PDF
Crossref (1)
Scopus Crossref
Publication Date
Sun Dec 01 2019
Journal Name
Baghdad Science Journal
Primary Colors Red, Yellow, and Blue Use as Self-Cleaning Paints with Layer of Titanium Dioxide
...Show More Authors

Transparent nano- coating was prepared by Sol-Gel method from titanium dioxide TiO2 which has the ability to self-cleaning coating used for hospitals, laboratories, and places requiring permanent sterilization. Three primary colors are selected (red, blue, and yellow) as preliminary study to the effect of these colors on the nano-coating. Three traditional oil paints color were used as base, then coated by a layer of TiO2-Sol and deposited on the paints. The optical properties of TiO2-Sol were measured; the maximum absorption wavelength at (λmax=387 nm), the refractive index (n=1.4423) and the energy band gap (Eg=3.2 eV). The structure properties found by X-ray diffraction of TiO

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Fri Oct 03 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Histological and histomorphometric analysis of strontium chloride coated commercially pure titanium implant compared with hydroxyapatite coating
...Show More Authors

Background: In recent years, the immediate loading of dental implants has become more accepted as a standard protocol for the treatment of the edentulous area. Success in implant dentistry depends on several parameters that may improve phenomenon of osseointegration and new bone formation in close contact with the implant. The aim of study was to evaluate the effect of strontium chloride coating of screw shape commercially pure titanium dental implant osseointegration at bone - implant interface by histomorphometric analysis and compare with hydroxyapatite coating at 2 time periods (2 weeks and 6 weeks). Materials and methods: Electrophoretic Deposition Technique (EPD) was used to obtain a uniform coating layer on commercially pure titanium

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 12 2019
Journal Name
International Journal Of Biosciences
Biomechanical and histological assessment of titanium dental implants coated with strontium substituted hydroxyapatite and fluorapatite mixture
...Show More Authors

Dental implants are considered a unique treatment alternative for the replacement of missing dentition. There is a strive for materials which increase bone formation in bone implant interface and improve osseointegration to offer immediate loading directly after placement with decreased time. The aim of the study was to assess the effect of nano strontium substituted hydroxyapatite and nano fluorapatite mixture coating of screw shaped commercially pure titanium at the bone implant interface by torque removal test and histological assessment in rabbit tibia. Commercially pure titanium was used to prepare 80 screws that were divided into machined surfaces (CpTi), coated with (SrHA), coated with (FA) and coated with mixture 50%SrHA + 50%FA (mi

... Show More
Preview PDF
Publication Date
Tue Jan 29 2019
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Using Quality and Accreditation standard in performance improvement of education institutions: بحث تطبيقي في كلية الهندسة جامعة بغداد
...Show More Authors

enjoyed the process of the development of higher education institutions attention of most countries of the world and to reconsider its objectives and programs and administrative and organizational structures, and it was the most important development of the application of Quality Assurance and Accreditation Standards (QAAS) tools, as the aim of these tools to the application of advanced with a far-reaching impact on all of the disciplines in the organization methods education that contribute, and plays a performance audit an important role in verifying the extent to which carried out these institutions activities or programs effectively and efficiently, economic, There are a number of objectives for the search of the most important attem

... Show More
View Publication Preview PDF
Crossref