Preferred Language
Sort By
Filters
Filter
Publication
Publication Date
Indexed In
Iraqi Journal of Laser Institute of Laser for Postgraduate Studies/ University of Baghdad
Journal Website
ISSN: 1812-1195
eISSN: 2618-0596
Statistics
No. of publications: 249
No. of views: 191037
No. of Crossref citations: 12
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Laser
PDF Towards C+L Band Three-Mode (De)Multiplexer Using Subwavelength Grating (SWG) Technology
...Show More Authors

Abstract: Recently, there is increasing interest in using mode-division multipelexing (MDM) technique  to enhace  data rate transmission over multimode fibers.  In this technique, each fiber mode is treated as a separate optical carrier to transfer its own data.  This paper presents a broadband, compact, and low loss three-mode (de)multiplexer designed for C+L band using subwavelength grating (SWG) technology and built-in silicon-on-insulator SOI platform. SWG offers refractive index engineering for wider operating bandwidth and compact devices compared to conventional ones. The designed (de)multiplex deals with three modes (TE0, TE1, and TE2) and has a loss > -1 dB and crosstalk < −15 dB, and its operation c

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Nanosecond Nd: YAG Laser Surface Cleaning of Metals and Marbles
...Show More Authors

Laser cleaning of materials’ surfaces implies the removal of deposited pollutants without affecting the material. Nanosecond Nd:YAG pulsed laser, operating at 1064 nm and 532nm, was utilized. Different laser intensities and number of pulses were used on metallic and non-metallic surfaces under O2 and Ar environments to remove metal oxide and crust. Cleaning efficiency was studied by optical microscope. The results indicated the superiority of 1064 nm over the 532 nm wavelength without any detectable damage to materials’ surfaces. Marble cleaned in Oxygen gas environment was better than in Ar gas.

View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Urinary Tract Stones Fragmentation using (2100 nm) Holmium: YAG Laser: (In vitro Analysis)
...Show More Authors

Urinary stones are one of the most common painful disorders of the urinary system. Four new technologies have transformed the treatment of urinary stones: Electrohydraulic lithotripsy, ultrasonic lithotripsy, extracorporeal shock wave lithotripsy, and laser lithotripsy.The purpose of this study is to determine whether pulsed holmium laser energy is an effective method for fragmenting urinary tract stones in vitro, and to determine whether stone composition affects the efficacy of holmium laser lithotripsy. Human urinary stones of known composition with different sizes, shapes and colors were used for this study. The weight and the size of each stone were measured. The surgical laser system which used in our study is Ho:YAG laser(2100nm)

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 15 2024
Journal Name
Iraqi Journal Of Laser
تقييم تأثير الدايود ليزر 1470 نانومتر في علاج البواسير الشرجية بطريقة تخثير الدم
...Show More Authors

 

الخلاصة:

الخلفية: البواسير هي مشكلة شرجية منتشرة في جميع أنحاء العالم، والتي يمكن أن تصيب عددًا كبيرًا من الأشخاص كل عام.  الأوردة في البواسير عندما تتوسع  وتتضخم فإنها ستتحول إلى حالة مرضية تسمى مرض البواسير. يستخدم الليزر بشكل رئيسي لقطع و/أو تخثر الأنسجة. في هذه الدراسة تم استخدام ليزر ديود 1470 نانومتر في 10 حالات مصابة ببواسير من الدرجة الثانية والثالثة والرابعة عن طريق&nb

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 15 2010
Journal Name
Iraqi Journal Of Laser
Photodynamic Inactivation of Candida Albicans Sensitized by Malachite Green
...Show More Authors

The aim of this study is to investigate the ability of malachite green (MG) combined with 650nm diode laser to kill Candida albicans and to spectrally study the MG photodegradation after photodynamic therapy (PDT) spectrally. Cultures of Candida albicans were exposed to 40mW, 650 nm diode laser in the absence of MG. In PDT group, the MG was added to the Candida suspension for 5 min then exposed to diode laser for (5, 10, 15, 20) min at power density of 0.59W/cm2. The absorption spectrum of the photosensitized fungal suspension was obtained. The data were submitted to T-test (p<0.05). A 650nm diode laser in the presence of MG reduced the number of CFU/ml in 98.4%. Laser with 650nm alone and MG alone did not reduce significantly the num

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 15 2024
Journal Name
Iraqi Journal Of Laser
كفاءة مادة البيروكسايد كاربمايد في ازالة التصبغات اللونية الداخلية للاسنان بمساعدة تقنيةليزر Er,Cr:YSSG المحتث بالأمواج الضوئية الصوتي ة
...Show More Authors

هدف البحث : تقييم تأثير تقنية الليزر المحتث بالامواج الضوئية الصوتية (PIPS) في تعزيز تغييرات لون الأسنان باستخدامالليزر Er ، Cr:YSGG مع بيروكسيد الكارباميد .

مواد وطرائق البحث : مجموعة من 42 سنًا سليمًا تم تضمينها في هذه الدراسة. تمت معالجة جميع الأسنان لبياً ثم تم تلوينها بشكل صناعي باستخدام دم الخروف ثم وضعت طبقة بسمك 3 مم من إسمنت الأيونومر الزجاجي (GIC) المعزز بالراتنج على مسافة2 مم تحت المَوصِ

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 15 2024
Journal Name
Iraqi Journal Of Laser
تشخيص متلازمة المبيض المتعدد الكيسات باستخدام مستويات هرمون التستوستيرونالحرة عبر تحليل رامان الطيفي المحسن للسطح بواسطة الذهب النانومتري ذو الشكل النجم ي
...Show More Authors

الخلفية: تظهر متلازمة المبيض المتعدد الكيسات (PCOS) على شكل انقطاع الإباضة، وندرة الطمث، وفرط الأندروجين لدى
النساء في سن الإنجاب، مما يؤثر على حوالي 5 - 10 ٪ من هذه الفئة من السكان . هناك حاجة ملحة لاتباع نهج سريع وغير مكلف وغير معقد للكشف نوعيًا وكميًا عن هرمون التستوستيرون الحر لدى المرضى الذين يعانون من متلازمة المبيض المتعدد الكيسات (PCOS).
المواد والطرق : استخدمت هذه الدراسة مطيافية رام

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Study the Effect of Annealing on Optical and Electrical Properties of ZnS Thin Film Prepared by CO2 Laser Deposition Technique
...Show More Authors

In this work, ZnS thin films have been deposited by developed laser deposition technique on glass substrates at room temperature. After deposition process, the films were annealed at different temperatures (200ºC , 300 ºC and 400ºC ) using thermal furnace.The developed technique was used to obtain homogeneous thin films of ZnS depending on vaporization of this semiconductor material by continuous CO2 laser with a simple fan to ensure obtaining homogeneous films. ZnS thin films were annealed at temperature 200ºC, 300 ºC and 400ºC for (20) minute in vacuum environment. Optical properties of ZnS thin film such as absorbance, transmittance, reflectance, optical band gap, refractive index extinction coefficient and absorption coefficien

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 15 2025
Journal Name
Iraqi Journal Of Laser
A comparative Efficacy of 635 nm and 980 nm Low-Level Laser Therapy in Treating Temporomandibular Disorders
...Show More Authors

Background: Temporomandibular disorders (TMDs) are a complex group of conditions impacting the temporomandibular joint (TMJ) and masticatory muscles, leading to pain, reduced jaw mobility, and other debilitating symptoms. These conditions often result from multifactorial causes, including malocclusion, trauma, stress, and parafunctional habits. Effective treatment is challenging, necessitating innovative therapeutic approaches.
Aim: This study compares the efficacy of two low-level laser therapy (LLLT) modalities with wavelengths of 635 nm and 980 nm in managing TMD symptoms. The goal is to determine which wavelength provides superior short-term and long-term therapeutic outcomes in pain relief, imp

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 15 2025
Journal Name
Iraqi Journal Of Laser
Circumcision by CO<sub>2</sub> laser 10600nm
...Show More Authors

Background: Male Circumcision is one of the most common surgical procedures performed in children. The indications for circumcision differ from country to country and might include both medical and religious ones.  Several different surgical procedures for circumcision have been documented, with various results and complications.

Aim of study: to evaluate the safety, effectiveness of the use of CO2 laser in circumcision and asses any possible post-operative complication(s).

Patients, Materials & Methods:  A prospective study was done for 26 patients who were circumcised by using a CO2 laser at 10600 nm from PLATIN, using continuous wave (CW) powe

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
Treatment of Skin Scar Using CO2 Laser with or Without Corticosteroid
...Show More Authors

CO2 Laser (10600nm) is the recent method in the management of challenging skin scar resulting from trauma, burn and surgical wound. The aim of this study was to evaluate the efficacy & safety of fractional CO2 laser (10600nm) in treatment of skin scar. Materials and Methods:Twenty patients with different types of scars treated with fractional CO2 (10600nm) laser, (10 patients) were given additional intralesional Triamcinolone. Results: All of the twenty patients included in this study showed some sort of improvements in scar texture, height and pliability and all of the ten patients who received intralesional Triamcinolone after laser show complete satisfaction. Conclusion:Fractional CO2 (10600nm) laser can be used as alternative, ef

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 24 2017
Journal Name
Iraqi Journal Of Laser
All Fiber Chemical Liquids Refractive Index Sensor Based on Multimode Interference
...Show More Authors

A simple all optical fiber sensor based on multimode interference (MMI) for chemical liquids sensing was designed and fabricated. A segment of coreless fiber (CF) was spliced between two single mode fibers to buildup single mode-coreless-single mode (SCS) structure. Broadband source and optical signal analyzer were connected to the ends of SCS structure. De-ionized water, acetone, and n-hexane were used to test the performance of the sensor. Two influence factors on the sensitivity namely the length and the diameter of the CF were investigated. The obtained maximum sensitivity was at n-hexane at 340.89 nm/RIU (at a wavelength resolution of the optical spectrum analyzer of 0.02 nm) when the diameter of the CF reduced from 125 μm to 60 μ

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Effects of 650 nm Diode Laser and 532 nm Frequency-Doubled Q-Switched Nd:YAG Laser on The Growth of Candida albicans, With and Without Photosensitizers
...Show More Authors

This work describes an experimental setup to evaluate the photodynamictoxicity of 650 nm diode laser and 532 nm Frequency-doubled Q-Switched Nd:YAG laser on the growth of Candida albicans as well as the potential fungicidal effect when combining the laser irradiation with specific photosensitizers namely methylene blue, toluidine blue, acridine orange and safranin O. In this study the findings showed that the number of colony-forming units per millilitre (CFU/ml) of C. albicans decreased with increasing exposure time. In particular in the case of the frequency doubled Nd:YAG laser combined with safranin O, the best lethal effect occurred at 11 minutes exposure time with 2.26 J/cm² energy density (89.18% reduction) in comparison with the

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 15 2018
Journal Name
Iraqi Journal Of Laser
Effect of 410 nm Diode Laser Irradiation on the Growth of Burn Wounds-associated Bacteria, Pseudomonas Aeruginosa and Staphylococcus Aureus
...Show More Authors

The effect of 410nm with 100 mW output power and one centimetre spot size (0.128 W/cm2 power density) Diode laser irradiation at different exposure times on the growth of Gram-negative Pseudomonas aeruginosa and Gram-positive Staphylococcus aureus was evaluated. Seventy swap samples were collected from burn and infected wounds of 35 patients admitted to the burn-wound unit in Al-Yarmouk Teaching Hospital in Baghdad during the period from December 2014 to February 2015. These bacteria were isolated and identified depending on their growth on selective media, cultural characteristics, Gram stain morphology and biochemical tests and finally were confirmed by Vitek 2 compact system test .Susceptibility of bacterial isolates to 15antibiotics

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 10 2009
Journal Name
Iraqi Journal Of Laser
A new achromatic glass for near infrared laser instruments
...Show More Authors

This research investigates new glasses which are best suitable for design of optical systems
working in the infrared region between 1.01 to 2.3μm. This work is extended to Oliva & Gennari
(1995,1998) research in which they found that the best known achromatic pairs are (BAF2-IRG2; SRF2-
IRG3; BAF2-IRG7; CAF2-IRGN6; BAF2-SF56A and BAF2-SF6). Schott will most probably stop the
production of these very little used and commercially uninteresting IRG glasses. In this work equally
good performances can be obtained by coupling BAF2, SRF2&CAF2 with standard glasses from Schott
or Ohara Company. The best new achromatic pairs found are (SRF2-S-TIH10; CAF2-S-LAL9; CAF2-SLAL13
and CAF2-S-BAH27). These new achromatic pai

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 15 2004
Journal Name
Iraqi Journal Of Laser
Interstitial Photocoagulation of Low Anal Fistula using 810 nm Diode Laser: Prospective Study
...Show More Authors

Many conservative sphincter-preserving procedures had been described to be effective in
healing of anal fistula without excision or de roofing.
Objective: To verify the outcome of mere photocoagulation of the fistula tract on healing of low anal
fistula.
Materials and Methods: Using 810nm diode laser, the tracts of low anal fistulae in a cohorts of six male
patients (mean age of 32 yr) had been photocoagulated by retrograde application of laser light through an
orb tip optical fiber threaded in to the tract. Swabs for culture and sensitivity testing were obtained before
and after laser application. Patients were followed up regularly to announce fistula healing.
Results: Mean laser exposure time was 6.6 min., mean

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 12 2019
Journal Name
Iraqi Journal Of Laser
Generation of True Random TTL Signals for Quantum Key-Distribution Systems Based on True Random Binary Sequences
...Show More Authors

A true random TTL pulse generator was implemented and investigated for quantum key distribution systems. The random TTL signals are generated by low cost components available in the local markets. The TTL signals are obtained by using true random binary sequences based on registering photon arrival time difference registered in coincidence windows between two single – photon detectors. The true random TTL pulse generator performance was tested by using time to digital converters which gives accurate readings for photon arrival time. The proposed true random pulse TTL generator can be used in any quantum -key distribution system for random operation of the transmitters for these systems

View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Effect of Laser Surface Modification on the Corrosion Resistance of Dental Alloys in Artificial Saliva Containing Alcoholic Beverages
...Show More Authors

The objective of this study is to demonstrate the corrosion behavior of dental alloys Co-Cr-Mo, Ni-Cr-Mo and Ti-Al-V in artificial saliva at pH=4 and 37oC enriched with ethyl alcohol at 8% percentage. The linear and cyclic polarizations were investigated by electrochemical measurements. Laser surface modification was achieved for the three dental alloys to improve corrosion resistance. The results show that corrosion resistance of Co-Cr-Mo and Ni-Cr-Mo alloys only were increased after laser treatment due to the fact that laser radiation has caused a smoother surface, in addition to the decrement in corrosion current densities (icorr) for Co-Cr-Mo and Ni-Cr-Mo alloys and the reverse scan in cyclic polarization became in the wider range of

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Enhancement of Episiotomy Healing Using (790-805) nm Diode Laser as a Supplementary Treatment
...Show More Authors

To show the impact of 790-805 nm diode laser irradiations on wound healing as a supplementary treatment in women underwent episiotomies, and to assess the laser parameters that were used .Material and methods: Eighteen female patients were included in this study; all of them underwent mediolateral episiotomy. Ten patients received laser therapy- diode laser (K Laser) (790-805) nm in CW mode of operation (and eight patients were the control group. Spot size of 8mm, time for exposure for each spot was 30 seconds. The power used was 0.6 W .The power density for each spot of treatment was 1.19 W/cm2 per session (non contact mode of application of laser therapy).The group studied received 2 sessions of laser radiation, day 4, and day 8 after

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 09 2019
Journal Name
Iraqi Journal Of Laser
Treatment of Oral Pyogenic Granuloma by 810 nm Diode Laser
...Show More Authors

Pyogenic granuloma is one of the inflammatory hyperplasia seen in the oral cavity. The
present study included 10 patients with pyogenic granuloma, involving 4 males and 6 females with 1:1.5
male to female ratio. Patient ages ranged from 5 to 85 years (mean, 30 years) and half of the lesions had
pedunculated base, with surface ulceration in 10% of cases. Treatment consisted of resection, using 810
nm diode lasers. Eight patients were anesthetized during the surgical operation by local infiltration of
anesthesia. Only three patients reported mild post-operative pain within the first 24 hours of the healing
period. During the surgical operation there was no significant bleeding so clear surgical field. There was
no blee

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 16 2008
Journal Name
Iraqi Journal Of Laser
Treatment of Oral Pyogenic Granuloma by 810 nm Diode Laser
...Show More Authors

Pyogenic granuloma is one of the inflammatory hyperplasia seen in the oral cavity. The
present study included 10 patients with pyogenic granuloma, involving 4 males and 6 females with 1:1.5
male to female ratio. Patient ages ranged from 5 to 85 years (mean, 30 years) and half of the lesions had
pedunculated base, with surface ulceration in 10% of cases. Treatment consisted of resection, using 810
nm diode lasers. Eight patients were anesthetized during the surgical operation by local infiltration of
anesthesia. Only three patients reported mild post-operative pain within the first 24 hours of the healing
period. During the surgical operation there was no significant bleeding so clear surgical field. There was
no blee

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Laser Induced Fluorescence Spectroscopy of Decamethylrhenocene ( - C5 Me5)2 Re in Supersonic Jet
...Show More Authors

In this paper we report the use of supersonic jet laser induced fluorescence (LIF) spectroscopy to facilitate the study of the spectra of some organometallic sandwich compounds particularly the metallocenes. The charge-transfer processes within these compounds, especially ligand to metal charge transfer within decamethylrhenocene ( - C5 Me5)2 Re were of particular interest. The spectrum shows a high degree of structures, indicating that there are several levels populated and these molecules are able to undergo many possible transitions

View Publication Preview PDF
Publication Date
Sat Jun 15 2024
Journal Name
Iraqi Journal Of Laser
The clinical evaluation of oral fibroma lesion removal utilizing two types of diode lasers 980 nm and 450 nm
...Show More Authors

يستخدم الليزرذو الصمام الثنائي بأطوال موجية مختلفة لما له من  فوائد كثيرة في جراحة اسئصال الافات الفموية الحميدة بسبب امتصاصة الجيد من قبل اصباغ الميلانين والهميغلوبين مع امتصاص ضعيف من قبل المياه والهيدروكسبيتات مما يجعله امنا للاسخدام حول الانسجة الصلبة والاسنان حيث يساعد على تقليل فترات شفاء المرضى والقدرة على تخثر الأنسجة عند الشقوق الجراحية  وألم أقل و تطهير موضع الجروح ، وكل ذلك يقلل من الحاجة

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 13 2005
Journal Name
Iraqi Journal Of Laser
Clinical Observation and Performance of High Power Diode Laser in the Treatment of Oral Lesions
...Show More Authors

In this work, oral lesions belong to 17 patients, 7 males and 10 females. Their ages range between 15 and 45 years. Follow up was conducted after one day, 7 days, 14 days, one month, and finally 3 months postoperatively. The study lasted for 1.5 year. Surgical diode laser with wavelength of 810 ± 20 nm, with two power levels of 10 and 15 W were used in contact and in non-contact mode via optical fiber. The postoperative outcome revealed; greater haemostatic capability, dry, sealed wound and noticeable lack in pain sensation

View Publication Preview PDF
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
Investigation of Nonlinear Optical Characteristics of the Multi-Wall Carbon Nanotubes (MWCNT's) Suspensions using Nonlinear Self-Diffraction of a Laser Beam
...Show More Authors

Nonlinear diffraction patterns can be obtained by focusing a laser beam through a thin slice of the material. Here, we investigated experimentally the formation of the far field nonlinear diffraction patterns of cw laser beam at 532 nm passing through a quartz cuvette containing multi-wall carbon nanotubes (MWCNT's) suspended in acetone and in DI water at concentrations of 0.030.wt.%, 0.045 wt.%, 0.060 wt.%, and 0.075 wt.%. Our results show that increasing the concentration of both types of suspensions (MWCNTs in acetone and MWCNTs DI water) led to increase in the number of pattern rings which indicates an increase in their nonlinear refractive indices. Moreover, MWCNTs DI water suspension at a concentration of 0.075 wt. % was more effic

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 15 2011
Journal Name
Iraqi Journal Of Laser
The Optical Limiting Behaviour of Prepared Silver Nanoparticles Embedded in Polymer Film
...Show More Authors

In the present work, silver nanoparticles were prepared. Nonlinear optical properties and
optical limiting of silver nanoparticles were investigated.Standard chemical synthesis method was used at
diffrent weight ratio(0.038, 0.058 and 0.078) of silver nitrate. Several testing were done to obtain the
characteristics of the sample. Z-Scan experiments were performed using 30 ns Q-switched Nd:YAG
laser at 1064 nm and 532 nm at different intensities. The results showed that the nonlinear refractive
index is directly proportional to the input intensities, which caused by the self-focusing of the material.
In addition, the optical limiting behavior has been studied. The results showed that the sample could be
used as an opt

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 10 2010
Journal Name
Iraqi Journal Of Laser
Generation of Weak Coherent Pulses for Quantum Cryptography Systems
...Show More Authors

This work is a trial to ensure the absolute security in any quantum cryptography (QC) protocol via building an effective hardware for satisfying the single-photon must requirement by controlling the value of mean photon number. This was approximately achieved by building a driving circuit that provide very short pulses (≈ 10 ns) for laser diode -LD- with output power of (0.7-0.99mW) using the available electronic components in local markets. These short pulses enable getting faint laser pulses that were further attenuated to reach mean photon number equal to 0.08 or less.

View Publication Preview PDF
Publication Date
Sat Dec 17 2022
Journal Name
Iraqi Journal Of Laser
PDF S and U shape offset studying of the refractive index sensor based on coreless fiber: Aya R. Mejble* Hanan J.Taher
...Show More Authors

Abstract:  Two different shapes of offset optical fiber was studied based on coreless fiber for refractive index (RI)/concentration (con.) measurement, and compare them. These shapes are U and S-shapes, both shapes structures were formed by one segment of coreless fiber (CF) was joined between two single mode (SMF) lead in /lead out with the same displacement (12.268µm) at both sides, the results shows the high sensitive was achieved in a novel S-shape equal 98.768nm/RIU, to our knowledge, no one has ever mentioned or experienced it, it’s the best shape rather than the U-shape which equal 85.628nm/RIU. In this research, it was proved that the offset form has a significant effect on the sensitivity of the sensor. Addi

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 15 2020
Journal Name
Iraqi Journal Of Laser
Hole Drilling of High Density Polyethylene using Nd:YAG Pulsed Laser
...Show More Authors

This paper presents the theoretical and experimental results of drilling high density
polyethylene sheet with thickness of 1 mm using millisecond Nd:YAG pulsed laser. Effects of laser
parameters including laser energy, pulse duration and peak power were investigated. To describe and
understand the mechanism of the drilling process Comsol multiphysics package version 4.3b was used to
simulate the process. Both of the computational and experimental results indicated that the drilling
process has been carried out successfully and there are two phases introduced in the drilling process,
vaporization and melting. Each portion of these phases depend on the laser parameters used in the
drilling process

View Publication Preview PDF
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
Gingival Enlargement Management using Diode Laser 940 nm and Conventional Scalpel Technique (A Comparative Study)
...Show More Authors

Diode lasers are becoming popular in periodontal surgery due to their highly absorption by pigments such as melanin and hemoglobin their weak absorption by water and hydroxyapatite makes them safe to be used around dental hard tissues. Objective: The aim of the present study was to evaluate the efficiency of diode laser in performing gingivectomy in comparison to conventional scalpel technique in patients with chronic inflammatory enlargement. Materials and methods: Thirty patients were selected for this study. All of them required surgical treatment of gingival enlargements and were randomly divided into two groups: Control group (treated by scalpel and include sixteen patients) and study group (treated with diode laser 940nm and includ

... Show More
View Publication Preview PDF