Background: This study aimed to use the combined mesio-distal crowns widths of maxillary incisors and first molars as predictors to the combined mesio-distal crowns widths of maxillary and mandibular canines and premolars. Materials and methods: The sample included 110 Iraqi Arab subjects with an age ranged between 17-25 years and class I skeletal and dental relations. The crown widths of maxillary teeth and mandibular canines and premolars were measured at the largest mesio-distal dimension on the study casts using digital electronic caliper with 0.01 mm sensitivity. Pearson’s correlation coefficient was used to determine the relation between the combined mesio-distal crowns widths of maxillary incisors and first molars and the combined mesio-distal crowns widths of maxillary and mandibular canines and premolars. Regression analysis was used to determine the equations that predict the widths of maxillary and mandibular canines and premolars. Paired sample t-test was used to compare between the actual and predicted mesio-distal crown widths. Results and Conclusions: The findings showed a non-significant difference between the predicted and actual mesio-distal crown widths; hence the combined mesio-distal widths of maxillary incisors and first molars can be used as predictors for the combined mesio-distal widths of maxillary and mandibular canines and premolars.
The complexity and partially defined nature of jet grouting make it hard to predict the performance of grouted piles. So the trials of cement injection at a location with similar soil properties as the erecting site are necessary to assess the performance of the grouted piles. Nevertheless, instead of executing trial-injected piles at the pilot site, which wastes money, time, and effort, the laboratory cement injection devices are essential alternatives for evaluating soil injection ability. This study assesses the performance of a low-pressure laboratory grouting device by improving loose sandy soil injected using binders formed of Silica Fume (SF) as a chemical admixture (10% of Ordinary Portland Cement OPC mass) to di
... Show MoreThe effective insulation design of the stress grading (SG) system in form-wound stator coils is essential for preventing partial discharges and excessive heat generation under pulse-width modulation excitation. This paper proposes a method to find the optimal insulation design of the SG system aimed at reducing the dielectric and thermal stresses in the machine coil. The non-uniform transmission line model is used to predict the voltage propagation along the overhang, SG, and slot regions considering the variation in the physical properties of the insulation layers. The machine coil parameters for different insulation materials are calculated by using the finite element method. Two optimization algorithms, fmincon and particle swarm optimiz
... Show MoreExtracorporeal shock wave lithotripsy (ESWL) is considered a standard treatment for nephrolith or kidney stones measuring less than 20 mm. Anatomical, machine-related, and stone factors play pivotal roles in treatment outcomes, the latter being the leading role. This paper examined the relationship between stone density on native CT scans and ESWL treatment to remove renal stones concerning several treatments. One hundred and twenty patients (64 males and 56 females) were enrolled and completed the study from April 2019 to September 2020. Inclusion criteria were a single renal pelvis stone of 5–20 mm to be treated for the first time in adult patients with no urinary or musculoskeletal anatomical abnormalities. We assessed patients
... Show MoreVarious assays are used to determine the toxic effects of drugs at cellular levels in vitro. One of these methods is the dye exclusion assay, which measures membrane integrity in the presence of Trypan blue. Trypan blue the dye which was used in this study to investigate cytotoxic effect of a new Cis –dichloroplatinum (II) complex [(Qu)2PtCl2] on the viability of polymorphonuclear cells (PMNs). Three concentrations of platinum complex were prepared (70, 35and 17.5 µg/ ml) and the results revealed that the percentage of cell viability decreased as the platinum complex concentration increased in comparison with control.
... Show MoreBackground. Implant insertion in regions with poor bone quantity, such as the posterior maxilla, is potentially associated with an increased rate of implant failure. Calcium sulfate can be used as the coating material for commercially pure titanium (CpTi) and as the bone graft material around implants when bound to eggshell powder to enhance the bone quality and quantity of bone defect regions. This study performed a torque removal test to evaluate the effectiveness of eggshell powder as a bone substitute for filling bone defects around CpTi-coated implants coated with nanocrystalline calcium sulfate. Materials and Methods. Eighty screw implant designs were used in the tibiae of 20 white New Zealand rabbits. A total of uncoated 20 s
... Show MoreA fixed firefighting system is a key component of fire safeguarding and reducing fire danger. It is installed as a permanent component in a structure to protect the entire or a portion of the building and its contents. The study aims to review the previous studies that deal with the evaluation of fire safety measures and their use in resolving problems associated with fire threats in buildings. For this reason, a number of previous studies in this field were reviewed compared with the NFPA code. The findings revealed that regulatory developments over the last several decades had created an atmosphere conducive to innovation. This has resulted in a growth in the number of fixed firefighting system types now obtainable. Th
... Show MoreConcrete columns with hollow-core sections find widespread application owing to their excellent structural efficiency and efficient material utilization. However, corrosion poses a challenge in concrete buildings with steel reinforcement. This paper explores the possibility of using glass fiber-reinforced polymer (GFRP) reinforcement as a non-corrosive and economically viable substitute for steel reinforcement in short square hollow concrete columns. Twelve hollow short columns were meticulously prepared in the laboratory experiments and subjected to pure axial compressive loads until failure. All columns featured a hollow square section with exterior dimensions of (180 × 180) mm and 900 mm height. The columns were categorized into
... Show MoreTo assess the biochemical, mechanical and structural characteristics of retained dentin after applying three novel bromelain‑contained chemomechanical caries removal (CMCR) formulations in comparison to the conventional excavation methods (hand and rotary) and a commercial papain‑contained gel (Brix 3000). Seventy‑two extracted permanent molars with natural occlusal carious lesions (score > 4 following the International Caries Detection and Assessment System (ICDAS‑II)) were randomly allocated into six groups (n = 12) according to the excavation methods: hand excavation, rotary excavation, Brix 3000, bromelain‑contained gel (F1), bromelain‑chloramine‑T (F2), and bromelain chlorhexidine gel (F3). The superficial and deepe
... Show More