Preferred Language
Articles
/
jbcd-195
Computed tomographic localization of infraorbital foramen position and correlation with the age and gender of Iraqi subjects
...Show More Authors

Background: The Infraorbital foramen is an anatomical structure with an important location in the maxilla, position of foramen in maxillofacial area is necessary in clinical situation requiring regional nerve blocks that are performed in children undergoing facial surgeries to avoid injury to corresponding nerve. The aim of study was to determine the position of the Infraorbital foramen and to correlate Infraorbital foramen position with age and gender using computed tomography. Subjects, Materials, and Methods: The sample consist of prospective study for 50 Iraqi subjects (21 male and 29 female) with age ranged from (5-17) years. The examination was performed on Multi – Slice Spiral Tomography scanner in Al-Karakh General Hospital. Using sagittal and coronal sections including right and left sides and the following measurements were done: 1. The distance from crista galli to the midpoint of fusion of hard palate(Midline of the patient) in the coronal section. 2. The distance from mid line to the infraorbital foramen, in the coronal section for both sides right and left. 3. The distance from sella turcica to the infraorbital foramen, in sagittal section for both sides right and left. 4. The distance from nasion to the infraorbital foramen, in coronal section for both sides right and left. Results: The partial regression coefficient for each year increase in age the linear measurements (midline-infraorbital foramen) (nasion-infraorbital foramen) and (vertical distance from nasion meeting the horizontal line from infraorbital foramen to midline) are expected to significantly increase after adjusting for confounding effect of gender. From multiple linear regression model designed in this study two mathematical formulae were derived for correlation of infraorbital foramen position with the age and gender:- Y1 [Linear measurement (Midline-Infraorbital foramen) mm] = 19.56 + (1.02 x gender) + (0.53x age in years). Y2 [Linear measurement (vertical distance from nasion meeting the horizontal line from Infraorbital foramen to midline)] = 28.42 + (2.5 x gender) + (0.30 x age in years). Conclusions: Computed tomography scan information facilitates the localization of infraorbital foramen position for successful access of the needle in infraorbital nerve block in children of different age and gender.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Feb 13 2018
Journal Name
Journal Of Optics
Solar selective performance of metal nitride/oxynitride based magnetron sputtered thin film coatings: a comprehensive review
...Show More Authors

View Publication
Scopus (30)
Crossref (20)
Scopus Clarivate Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
CATHODIC PROTECTION OF CARBON STEEL IN 0.1N NaCl SOLUTION UNDER FLOW CONDITIONS USING ROTATING CYLINDER ELECTRODE
...Show More Authors

The effect of applied current on protection of carbon steel in 0.1N NaCl solution (pH=7) was investigated under flow conditions (0-0.262 m/s) for a range of temperatures (35-55°C) using rotating cylinder electrode. Various values of currents were applied to protect steel from corrosion, these were Iapp.=Icorr., Iapp.=2Icorr. and Iapp.=2.4Icorr. under stationary and flow conditions. Corrosion current was measured by weight loss method. The variation of protection potential with time and rotation velocity at various applied currents was assessed. It is found that the corrosion rate of carbon steel increases with rotation velocity and
has unstable trend with temperature. The protection current required varies with temperature and it inc

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Jun 01 2018
Journal Name
Journal Of Engineering
Experimental Study of Optimum Chilled Water Distribution Configuration in Air Conditioning Terminal Unit Using RSM Technique
...Show More Authors

The distribution of chilled water flow rate in terminal unit is an important factor used to evaluate the performance of central air conditioning unit. A prototype of A/C unit has been made, which contains three terminal units with a complete set of accessories (3-way valve, 2-way valve, and sensors) to study the effect of the main parameters, such as total water flow rate and chilled water supply temperature with variable valve opening. In this work, 40 tests were carried out. These tests were in two groups, 20 test for 3-way valve case and 20 test for 2-way valve case. These tests were performed at three levels of valve opening, total water flow rate and water supply temperature according to the design matrices establis

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue May 30 2017
Journal Name
Environmental Earth Sciences
Purification of aqueous solutions from Pb(II) by natural bentonite: an empirical study on chemical adsorption
...Show More Authors

View Publication
Scopus (15)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Sun Jul 01 2012
Journal Name
Ieee Transactions On Geoscience And Remote Sensing
Echo Amplitude Normalization of Full-Waveform Airborne Laser Scanning Data Based on Robust Incidence Angle Estimation
...Show More Authors

View Publication
Scopus (26)
Crossref (22)
Scopus Clarivate Crossref
Publication Date
Mon Mar 23 2020
Journal Name
Baghdad Science Journal
Surfactant Cloud Point Extraction as a Procedure of Preconcentrating for Metoclopramide Determination Using Spectro Analytical Technique
...Show More Authors

In current article an easy and selective method is proposed for spectrophotometric estimation of metoclopramide (MCP) in pharmaceutical preparations using cloud point extraction (CPE) procedure. The method involved reaction between MCP with 1-Naphthol in alkali conditions using Triton X-114 to form a stable dark purple dye. The Beer’s law limit in the range 0.34-9 μg mL-1 of MCP with r =0.9959 (n=3) after optimization. The relative standard deviation (RSD) and percentage recoveries were 0.89 %, and (96.99–104.11%) respectively. As well, using surfactant cloud point extraction as a method to extract MCP was reinforced the extinction coefficient(ε) to 1.7333×105L/mol.cm in surfactant-rich phase. The small volume of organi

... Show More
View Publication Preview PDF
Scopus (13)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Tue Mar 13 2018
Journal Name
Mustansiria Dental Journal
Dimensional stability of heat-activated acrylic resin at different time intervals by different flask cooling methods
...Show More Authors

This study was design to investigate the dimensional stability of heat-activated acrylic resin with different methods of flask cooling (15 minutes rapid cooling, one hour bench cooling, four hours delayed deflasking, and 24 hours delayed deflasking) at different time intervals (immediately, two days, seven days, 30 days) after deflasking. Heat-activated acrylic resin was used to prepare acrylic samples. Then, measurement of the distances where achieved between the centers of selected marks in the acrylic samples. They were measured at different time intervals for different methods of flask cooling. The results showed that the group samples of the four hours and 24 hours of delayed deflasking was insignificantly different from the control an

... Show More
Preview PDF
Publication Date
Sat Nov 30 2024
Journal Name
Iraqi Journal Of Science
Effects of Phenolic Plant Extracts on Biofilm Formation by Klebsiella pneumoniae Isolated from Urinary Tract Infections
...Show More Authors

Ten isolates of Klebsiella pneumoniae, seven isolates of Pseudomonas aeruginosa and nine isolates of Staphylococcus aureus, were obtained from 100 urine samples collected from Baghdad hospitals. All isolates were identified biochemically and confirmed by using VITEK 2 and were then tested for their susceptibility towards 6 antibiotics and for phenolic extracts of Thymus vulgaris and Cinnamomum cassia. All bacteria were greatly affected by T. vulgaris, especially K. pneumoniae. Viable count was performed, it was noted that the number of bacterial cells reduced from 1×108 CFU to 1.2× 103, 2×105 and 1.8×106CFU of K. pneumoniae, P. aeruginosa and S. aureus respectively. While C. cassiahad a slight effect on them. K. pneumoniae isola

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sun Jul 01 2018
Journal Name
Computers And Electronics In Agriculture
Detection of charcoal rot (Macrophomina phaseolina) toxin effects in soybean (Glycine max) seedlings using hyperspectral spectroscopy
...Show More Authors

View Publication
Scopus (16)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Engineering
Efficient Energy Management for a Proposed Integrated Internet of Things-Electric Smart Meter (2IOT-ESM) System
...Show More Authors

In this work, an efficient energy management (EEM) approach is proposed to merge IoT technology to enhance electric smart meters by working together to satisfy the best result of the electricity customer's consumption. This proposed system is called an integrated Internet of things for electrical smart meter (2IOT-ESM) architecture. The electric smart meter (ESM) is the first and most important technique used to measure the active power, current, and energy consumption for the house’s loads. At the same time, the effectiveness of this work includes equipping ESM with an additional storage capacity that ensures that the measurements are not lost in the event of a failure or sudden outage in WiFi network. Then then these

... Show More
View Publication Preview PDF
Crossref (2)
Crossref