Aortic valve replacement (AVR) is the gold standard method for management of severe aortic stenosis (AS), with transcatheter balloon valvoplasty (BAV) increasingly used as palliative option for calcified valve in experienced hand. In the AVR era, BAV was not considered a long-term definitive treatment for severe calcific AS due to a high restenosis rate and short durability of gradient improvement. However, it continues to have an important role as a bridge-to-decision or bridge-to-intervention in cases where definitive therapy must be delayed due to clinical instability, imaging uncertainty or failed trial of surgical valve replacement. We report a case of heavily calcified AS in an adolescent female, in which the calcification involves the ascending aorta extending to the aortic arch with failure of surgical management trail and she finally managed by transcatheter balloon valvoplasty
Background: Aortic valve stenosis results from minor to severe degrees of aortic valve maldevelopment. This stenosis causes mild to severe obstruction of the left ventricular outflow .
Objectives : to study the immediate and intermediate results of percutaneous balloon aortic valvuloplasty in patients with congenital valvular aortic stenosis .
Type of the study: A prospective study.
Methods: The study was done on thirty five patients with congenital valvular aortic stenosis who had percutaneous balloon aortic valvuloplasty in Ibn Al- Bitar Center for Cardiac Surgery from May 2009 to February 2011.
Results
... Show MoreBackground: Among individuals who have a stenotic aortic valve, a precise assessment of aortic valve area is essential for clinical judgment. So far, no studies have been conducted to investigate and assess the role of the three dimensional echo-cardiography in the assessment of the valve stenosis. This study aims to compare and assess the precision of the measurement of the stenosis area of the aortic valve by 2D versus 3D echo-cardiography.
Reintervention after balloon angioplasty is often considered inevitable in children with coarctation of the aorta (COA). The present study aimed to evaluate predictors of re-intervention after balloon angioplasty for COA, with the goal of identifying patient and procedural characteristics that may influence long-term outcomes
Background: Mitral valve stenosis is a condition in which the hearts mitral valve is narrowed (stenosis), This narrowing blocks the valve from opening properly obstructing blood flow through the heart and the rest of the body and this causes changes in physical parameters (resistance and conductance). Aim of the study: To assess the changes in the physical parameters in mitral valve stenosis disease in different gender and age by using Doppler ultrasound. Methods : The examination of patients at the Division of Echo - at the Iraqi Center for Heart Disease in Medical City for surgery specialist - Baghdad - Iraq, during(February2009 till November2010). The current study included fifty eight cases containing (27 males and 31 females) ages rang
... Show MoreTetralogy of Fallot (TOF) is the most prevalent cyanotic congenital heart disease, for which surgical correction remains the definitive treatment. Balloon dilatation of the pulmonary artery provides recognised immediate palliative benefits in selected TOF patients. Nonetheless, optimal patient selection and midterm outcomes remain subjects of ongoing debate. This study aimed to assess midterm results following pulmonary valvoplasty at 6 months period in children with TOF focusing on defining factors that affect response to palliative therapy
Background: Infantile hypertrophic pyloric
stenosis affects 0.5 – 3.0 per 1000 live birth and it is
the most common surgical cause of vomiting in
infancy.
Objective: To analyze variable peri-natal factors
that may be involved in the etiology of infantile
hypertrophic pyloric stenosis.
Methods: Over a two year's period, from January
2000 – December 2001, 31 cases of infantile
hypertrophic pyloric stenosis were evaluated for
variable peri-natal risk factors in AL-Eskan central
child teaching hospital for children.
Results: The 31 cases studied were 77.4% males
and 48.4% at three weeks of age. And of all cases,
51.6% were breast fed with a blood group (O) being
the predominant in 54.8%.
No
This valve is intended for use in valves for steering movement, using the qualities of the Magneto-rheological (MR) fluid to regulate the fluid, direct contact without the utilization of moving parts like a spool, a connection between electric flux, and fluid power was made, The simulation was done to employ the" finite element method of magnetism (FEMM)" to arrive at the best design. This software is used for magnetic resonance valve finite element analysis. The valve's best performance was obtained by using a closed directional control valve in the normal state normally closed (NC) MR valve, with simulation results revealing the optimum magnetic flux density in the absence of a current and the shedding condition, as well as the optimum
... Show MoreProtection of the oil pipelineswhich extracted from the wells was found to shut the well and prevent the leakage of oil when broken using safety valve. This valve is automatically activated by loss of pressure between the well and pipelines, which take the pressure, signal from hydraulic pressure sensor through pressure control valve which has constant or variable value but it is regulated manually. The manual regulatory process requires the presence of monitoring workers continuously near the wells which are always found in remote areas. In this paper, a smart system has been proposed that work with proportional pressure control valve and also electronic pressure sensor through Arduino controller, which is programmed in a way that satisfie
... Show MoreThe main part in hydraulic system is directional control valve. Directional control valve has complex construction such as moving spool to control the direction of actuator for required speed. Magneto-rheological (MR) fluid is one of controllable fluids. Utilizing the MR fluid properties, direct interface can be realized between magnetic field and fluid power without the need for moving parts like spool in directional control valves. This study proposes the design of four ways/three position MR proportional directional control valve (4/3 MR valve). The construction of valve and the principle of work are presented. Analysis for magnetic circuit and simulation for valve performance were done. The experiment was conducted to show the principle
... Show More