Influence of Nanofluid Flooding on Oil Displacement in Porous Media
...Show More Authors

Hydrocarbon displacement at the pore scale is mainly controlled by the wetness properties of the porous media. Consequently, several techniques including nanofluid flooding were implemented to manipulate the wetting behavior of the pore space in oil reservoirs. This study thus focuses on monitoring the displacement of oil from artificial glass porous media, as a representative for sandstone reservoirs, before and after nanofluid flooding. Experiments were conducted at various temperatures (25 – 50° C), nanoparticles concentrations (0.001 – 0.05 wt% SiO2 NPs), salinity (0.1 – 2 wt% NaCl), and flooding time. Images were taken via a high-resolution microscopic camera and analyzed to investigate the displacement of the oil at different conditions. In addition, contact angle measurements on quartz surfaces were also conducted at similar conditions to understand the flow behavior in the porous media. Further, zeta potential and particle size distribution measurements were conducted to examine the stability of the injected nanofluids. Results revealed that the injection of nanofluids into oil-wet pore space can significantly enhance the recovery rate of hydrocarbon by altering the wettability of the porous media. However, salinity, particularly at high nanoparticles concentration (≥ 0.005) can dramatically reduce the efficiency of nanofluid. Further, increased aging time can improve the ability of nanofluid to alter the wettability of the surface, and thus more oil can be displaced. Thus, nanofluid can efficiently enhance oil recovery if correctly formulated.

Crossref
View Publication
Publication Date
Tue Feb 28 2017
Journal Name
Journal Of Engineering
Design and Implementation of Enhanced Smart Energy Metering System
...Show More Authors

In this work, the design and implementation of a smart energy metering system has been developed. This system consists of two parts: billing center and a set of distributed smart energy meters. The function of smart energy meter is measuring and calculating the cost of consumed energy according to a multi-tariff scheme. This can be effectively solving the problem of stressing the electrical grid and rising consumer awareness. Moreover, smart energy meter decreases technical losses by improving power factor. The function of the billing center is to issue a consumer bill and contributes in locating the irregularities on the electrical grid (non-technical losses). Moreover, it sends the switch off command in case of the consumer bill is not

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 01 2015
Journal Name
Baghdad Science Journal
Terrestrial Invertebrates as a Bioindicators of Heavy Metals Pollution
...Show More Authors

Bioaccumulation of heavy metals in the terrestrial invertebrates in Al-Jadriyia district Baghdad- Iraq were investigated. Forth terrestrial invertebrates snails, slug, isopods, and diplopods , were selected for this study. The results showed that all invertebrate groups have the ability in accumulate considerable amounts of heavy metals. Higher levels of zinc and copper were observed in the isopods specimens, it's about ( 60.50±0.58 ) and ( 96.00±0.58 ) ppm respectively , while higher levels of lead were observed in the diplopods specimens ,it's about ( 23.00±1.15 ) ppm ,but the higher levels of both iron and cadmium were observed in snail specimens , it's about ( 590.00±1.15 ) and ( 9.50±1.15 ) ppm respectively .but the

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Dec 02 2012
Journal Name
Baghdad Science Journal
Bacterial contamination of AL-Habania and AL-Tharthar reservoirs
...Show More Authors

Bacterial contamination of AL-Habania and AL-Tharthar reservoirs were studied during the period from February 2001 to January 2002, samples were collected from four stations in AL-Habania reservoir (AL-Warrar, AL-Theban regulator, middle of the reservoir and the fourth was towards AL-Razzaza reservoir) and from two stations at AL-Tharthar reservoir (Ein AL-Hilwa and the middle of the reservoir). Coliform bacteria, faecal Coliforms, Streptococci, faecal Streptococci and total count of bacteria were used as parameters of bacterial contamination in waters of both reservoirs through calculating the most probable number. Highest count of Coliform bacteria (15000 cell/100ml) was recorded at Ein AL-Hilwa and lowest count at AL-Theban regulator

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Sep 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Tetracycline from Wastewater Using Circulating Fluidized Bed
...Show More Authors

   In this study, the circulating fluidized bed was used to remove the Tetracycline from wastewater utilizing a pistachio shell coated with ZnO nanoparticles. Several parameters including, Tetracycline solution flowrate, initial static bed height, Tetracycline initial concentration and airflow rate were systematically examined to show their effect on the breakthrough curve and the required time to reach the adsorption capacity and thus draw the fully saturated curve of the adsorbent. Results showed that using ZnO nanoparticles will increase the adsorbent surface area and pores and as a result the adsorption increased, also the required time for adsorbent saturation increased and thus the removal efficiency may be achieved at mi

... Show More
View Publication Preview PDF
Crossref (19)
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
E3s Web Of Conferences
Selecting Appropriate Delivery System for Implementation of Green Buildings
...Show More Authors

Green buildings are considered more efficient than traditional buildings due to the incorporated techniques and the multidisciplinary specializations required to comply with their specifications, in addition to the advanced commissioning, which undergoes before handing over the buildings to the owners to ensure requirements conformance. As a result, the appropriate selection of a project delivery system acts as the essential factor that affects the performance of the project. This research aims at building a system that helps to select the best method to implement green buildings. Through studying the recent research approaches in project delivery systems, the factors that affect the selection of the optimal implementation method fo

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Characterization of CuO thin films for gas sensing applications
...Show More Authors

Nanostructural cupric oxide (CuO) films were prepared on Si and glass substrate by pulsed laser deposition technique (PLD) using laser Nd:YAG, using different laser pulses energies from 200 to 600 mJ. The X-ray diffraction pattern (XRD) of the films showed a polycrystalline structure with a monoclinic symmetry and preferred orientation toward (111) plane with nano structure. The crystallite size was increasing with increasing of laser pulse energy. Optical properties was characterized by using UV–vis spectrometer in the wave lengthrange (200-1100) nm at room temperature. The results showed that the transmission spectrum decreases with the laser pulses energy increase. Sensitivity of NO2 gas at different operating temperatures, (50°C,

... Show More
View Publication Preview PDF
Crossref (11)
Crossref
Publication Date
Mon Jul 10 2023
Journal Name
Journal Of Engineering
Design and Implementation of Single-Phase Boost PFC Converter
...Show More Authors

In this paper, a single-phase boost type ac-dc converter with power factor correction (PFC) technique is designed and implemented. A current mode control at a constant switching frequency is used as a control strategy for PFC converter. The PFC converter is a single-stage singleswitch boost converter that uses a current shaping technique to reshape the non-sinusoidal input current drawn by the bulky capacitor in the conventional rectifier. This technique should provide an input current with almost free-harmonics, comply with the IEC61000-3-2 limits, and a system operates with near unity power factor. The other function of the boost converter that should be
accomplished is to provide a regulated DC output voltage. The complete designed

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Feb 14 2024
Journal Name
2nd International Conference For Engineering Sciences And Information Technology (esit 2022): Esit2022 Conference Proceedings
Manufacture of wooden furniture paint using pistachio shell waste
...Show More Authors

View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Wed Oct 25 2023
Journal Name
Plos One
Performance enhancement of high order Hahn polynomials using multithreading
...Show More Authors

Orthogonal polynomials and their moments have significant role in image processing and computer vision field. One of the polynomials is discrete Hahn polynomials (DHaPs), which are used for compression, and feature extraction. However, when the moment order becomes high, they suffer from numerical instability. This paper proposes a fast approach for computing the high orders DHaPs. This work takes advantage of the multithread for the calculation of Hahn polynomials coefficients. To take advantage of the available processing capabilities, independent calculations are divided among threads. The research provides a distribution method to achieve a more balanced processing burden among the threads. The proposed methods are tested for va

... Show More
View Publication
Scopus (7)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Thu Jun 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A Review of the Electrical Submersible Pump Development Chronology
...Show More Authors

The electric submersible pump, also known as ESP, is a highly effective artificial lift method widely used in the oil industry due to its ability to deliver higher production rates compared to other artificial lift methods. In principle, ESP is a multistage centrifugal pump that converts kinetic energy into dynamic hydraulic pressure necessary to lift fluids at a higher rate with lower bottomhole pressure, especially in oil wells under certain bottomhole condition fluid, and reservoir characteristics. However, several factors and challenges can complicate the completion and optimum development of ESP deployed wells, which need to be addressed to optimize its performance by maximizing efficiency and minimizing costs and uncertainties. To

... Show More
View Publication Preview PDF
Crossref (7)
Crossref