Preferred Language
Articles
/
73m2aqEBuRolNscLlgKM
A scanning electron microscopy investigation of the precision of three orthodontic bracket slot systems
...Show More Authors
Abstract<sec> <title>Objective

One of the most imprortant factors in achieving ideal teeth positions is the precision of the slot dimensions of orthodontic brackets into the archwires are inserted.This study aimed to assess the accuracy of the dimensions of orthodontic bracket slots and molar buccal tube apertures and to compare them with the specifications provided by the manufacturers.

Method

A total of sixty brackets and ten molar buccal tubes with varying slot heights were examined using a scanning electron microscope from the mesial side. The dimensions and morphology of these bracket slots and buccal tubes apertures were assessed using the AutoCAD Software. A one-sample t-test was conducted to compare the measurements with the values provided by the manufacturer.

Results

The findings of the present study indicated that the height of the measured bracket slots and buccal tube apertures dimensions were significantly larger than the actual dimensions and exhibiting divergent walls. On the other hand, the depth of the brackets slots showed significantly smaller values than the actual one.

Conclusion

A need for careful consideration when selecting a commercially accessible brand for everyday use is essential as certain materials may not meet acceptable standards.

Scopus Crossref
View Publication
Publication Date
Fri Sep 01 2023
Journal Name
Journal Of Orthodontic Science
Evaluating orthodontic bracket slot dimensions and morphology: A narrative review
...Show More Authors

The current article aims to review the previous studies that measure the orthodontic bracket slot dimensions and geometry. Searches in different databases, including PubMed Central, Science Direct, Wiley Online Library, the Cochrane Library, Textbooks, Google Scholar, and Research Gate, in addition to a manual search, were performed about the methods of assessing orthodontic bracket slot dimension up to March 2023. The irrelevant and duplicate studies were eliminated, leaving 35 studies for this narrative review. The findings indicate that the slots are oversized with diverging walls in most studies. Manufacturers must respect the standards during manufacturing brackets and adhere to the actual dimensions and tolerance values.

... Show More
View Publication
Scopus (6)
Crossref (6)
Scopus Crossref
Publication Date
Wed Jul 11 2018
Journal Name
European Journal Of Orthodontics
A randomized clinical trial of the effectiveness of 0.018-inch and 0.022-inch slot orthodontic bracket systems: part 2—quality of treatment
...Show More Authors
Summary<sec><title>Objective

To compare the quality of orthodontic treatment between 0.018-inch and 0.022-inch slot bracket systems.

Subjects and methods

Eligible participants aged 12 years or over were allocated to the 0.018-inch or 0.022-inch slot MBT appliance (3M-Unitek, Monrovia, California, USA) using block randomization in groups of 10. Outcome measures included: 1. ABO cast-radiograph evaluation (CR-EVAL), 2. peer assessment rating (PAR) scores, 3. incisor inclination, and 4. patient perception using the Index of Orthodontic Treatment Need aesthetic component (IOTN AC) and three validated questionnaires before, during

... Show More
View Publication
Crossref (23)
Crossref
Publication Date
Wed Jul 11 2018
Journal Name
European Journal Of Orthodontics
A randomized clinical trial of the effectiveness of 0.018-inch and 0.022-inch slot orthodontic bracket systems: part 1—duration of treatment
...Show More Authors

View Publication
Crossref (20)
Crossref
Publication Date
Wed Jul 11 2018
Journal Name
European Journal Of Orthodontics
A randomized clinical trial of the effectiveness of 0.018-inch and 0.022-inch slot orthodontic bracket systems: part 3—biological side-effects of treatment
...Show More Authors

View Publication
Crossref (21)
Crossref
Publication Date
Mon Jul 01 2019
Journal Name
The Angle Orthodontist
Does anchorage loss differ with 0.018-inch and 0.022-inch slot bracket systems?
...Show More Authors
ABSTRACT<sec id="st1"> <title>Objectives:

To compare maxillary first molar anchorage loss between 0.018-inch and 0.022-inch slot fixed appliance systems.

Materials and Methods:

Patients requiring bilateral maxillary premolar extractions (n = 74) within a randomized clinical trial comparing the effectiveness of 0.018-inch and 0.022-inch slot MBT bracket systems (3M-Unitek, Monrovia, Calif) were included. Three-dimensional pre- and posttreatment digital models were landmarked and me

... Show More
View Publication
Crossref (9)
Crossref
Publication Date
Wed Jul 03 2019
Journal Name
Scientific Reports
A Novel Etchant System for Orthodontic Bracket Bonding
...Show More Authors
Abstract<p>Orthodontic treatment is widely used to correct irregular teeth and/or jaw discrepancies to improve oral function and facial aesthetics. However, it is frequently associated with enamel damage that include chipping, demineralisation, and white spot formation. So far, current bonding systems that can maintain shear bond strengths (SBS) suitable for clinical performance are unable to limit enamel demineralisation, adhesive remnants and damage caused on removal of brackets after treatment. This study reports a novel “safe enamel etch” clinically viable procedure that was accomplished via application of novel etchant pastes developed with β-tricalcium phosphate and monocalcium phosphate monohydrate </p> ... Show More
View Publication
Scopus (39)
Crossref (34)
Scopus Crossref
Publication Date
Sun Sep 01 2019
Journal Name
International Orthodontics
Variation in bracket slot sizes, ligation methods and prescriptions: UK national survey
...Show More Authors

View Publication
Crossref (5)
Crossref
Publication Date
Sat May 01 2021
Journal Name
Journal Of Physics: Conference Series
Characteristics of probing electrons behavior inside the chamber of scanning electron microscope
...Show More Authors
Abstract<p>The electron mirror phenomenon has been explored to describe the behavior of a probing electron trajectory inside the chamber of scanning electron microscope (SEM). This investigation has been carried out by means of the modulated mirror plot curve technique. This method is based on expanding sample potential to a multipolar form to detect the actual distribution of the trapped charges. Actually an experimental result is used to guiding results of this work toward the accurate side. Results have shown that the influence of each type of multipolar arrangement (monopole, dipole, quadruple, octopole … etc.) mainly depends on the driving potential.</p>
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Tue Oct 02 2018
Journal Name
Iraqi Journal Of Physics
The efficiency calibration for local manufacturing gamma scanning systems of radioactive waste drums
...Show More Authors

The Local manufacturing scanning gamma system designed in Tuwaitha site for nondestructive assay method of radioactive waste drums, where it consist of two main parts with their belongings for controlling the of detector and drum movements up-down and rotation respectively. The volume of the used drum is 220 L with 85 cm height. The drum filled with Portland cement. Six cylindrical holes were made within cement drum and distributed in radial arrangement.The152Eu source inserted in these holes individually, to measure the average angular count rate of gamma radiation. The full energy efficiency value for geometry of drum and detector is computed for thirteen photo peaks. The average efficiency represented by the curve of these peaks indic

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jun 15 2020
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of different bracket types on streptococcus mutans count in orthodontic patients using fluoridated toothpaste
...Show More Authors

Background: Plaque retention during fixed orthodontic therapy is an important cause of developing enamel demineralization. The purpose of this study was to evaluate the effect of different brackets types on the count of Streptococcus Mutans in orthodontic patients using conventional fluoridated toothpaste. Materials and Methods: Plaque samples were collected from maxillary 1st premolar teeth of twenty right handed patients (using split mouth technique) before bonding, after 48 hrs of bonding using tooth brush only, and after 2 weeks of using fluoridated toothpaste. Stainless steel bracket was bonded on right first premolar while the left one was bonded with sapphire bracket. The calculation of the Streptococcus Mutans count was done usin

... Show More
View Publication Preview PDF
Scopus (12)
Crossref (7)
Scopus Crossref