In vitro apical microleakage evaluation for different endodontic sealers by spectrophotometric analysis: an observational study
...Show More Authors

Background: It has been established that several filling techniques can affect apical leakage, which is responsible for 59% of endodontic failures. The primary goal of endodontic therapy is to create a tight seal that aids in repairing the periapical tissues, prevents apical periodontitis, and shields against root canal infection. The study aims to compare the apical sealing ability of epoxy resin based sealer  (AH plus), which is an epoxy-resin-based root canal sealer, GuttaFlow 2, which is a silicone-based root canal sealer, GuttaFlow bioseal is a bioactive glass-based root canal sealer, TotalFill HiFlow bioceramic (BC) sealer is a silicate-based root canal sealer (bioceramic sealer) using a single cone technique by spectrophotometric analysis.

 Methods: This study chose 64 maxillary first molars with a straight palatal root. Following palatal roots sectioning to 11 mm from the root apex, the canals were instrumented up to size X4 using Protaper Next. They were separated into  four experimental groups (n = 15) per each group based on the kind of sealer utilized, Group I: AH plus, Group II: GuttaFlow 2, Group III: GuttaFlow bioseal, Group IV: TotalFill BC HiFlow, and two control groups (n =2 for each).  After completing obturation, the dye extraction technique was used to evaluate apical leakage. A spectrophotometer was used to measure the optical density of the solution after all the dyes were liberated from the interfacial regions.

Result: A statistically non-significant difference between the investigated root canal sealers in apical microleakage P > 0.05 was noted. The highest mean values were observed in group IV (0.08046), group I(0.07731), and group II(0.06209), while the lowest mean value in group III (0.05719)

Conclusions: All types of sealers used in this investigation showed various amounts of microleakage. None of the sealants could completely close the apical foramen to provide a fluid-tight seal.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Mar 04 2022
Journal Name
Journal Of Water Resources And Geosciences
A Review Study on Gypseous Soils Stabilized with Different Additives in Iraq
...Show More Authors

View Publication
Publication Date
Fri Jan 01 2010
Journal Name
Iraqi Journal Of Biotechnology
BIOCHEMICAL STUDY ON SUPEROXIDE DISMUTASE ENZYME IN PATIENTS WITH DIFFERENT BRAIN TUMORS
...Show More Authors

The aim of the current study is to in evaluate the role of SOD activity in the previously reported oxidative stress in our laboratory(1), in the patients with different brain tumors. SOD activity was assayed according to riboflavin/NBT method and its specific activity was calculated in patients with benign and malignant brain tumors and control. Moreover the specific activity was compared in these samples according to gender and the occurrence of disease.Non significant elevation (P > 0.05) in SOD specific activity was observed in tissue of malignant tumors in comparison to that of in benign brain tumors. While a highly significant decrease (P < 0.001) of the specific activity was found in sera of malignant patients group in comparison to t

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 31 2019
Journal Name
Journal Of Engineering
Buckling Analysis of Laminated Composite Plate with Different Boundary Conditions using modified Fourier series
...Show More Authors

Buckling analysis of a laminated composite thin plate with different boundary conditions subjected to in-plane uniform load are studied depending on classical laminated plate theory; analytically using (Rayleigh-Ritz method). Equation of motion of the plates was derived using the principle of virtual work and solved using modified Fourier displacement function that satisfies general edge conditions. The eigenvalue problem generated by using Ritz method, the set of linear algebraic equations can be solved using MATLAB for symmetric and anti-symmetric, cross and angle-ply laminated plate considering some design parameters such as aspect ratios, number of layers, lamination type and orthotropic ratio. The results obtained g

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Jun 01 2020
Journal Name
Al-khwarizmi Engineering Journal
Analysis of Different Hand and Finger Grip Patterns using Surface Electromyography and Hand Dynamometry
...Show More Authors

Recording an Electromyogram (EMG) signal is essential for diagnostic procedures like muscle health assessment and motor neurons control. The EMG signals have been used as a source of control for powered prosthetics to support people to accomplish their activities of daily living (ADLs). This work deals with studying different types of hand grips and finding their relationship with EMG activity. Five subjects carried out four functional movements (fine pinch, tripod grip and grip with the middle and thumb finger, as well as the power grip). Hand dynamometer has been used to record the EMG activity from three muscles namely; Flexor Carpi Radialis (FCR), Flexor Digitorum Superficialis (FDS), and Abductor Pollicis Brevis (ABP) with different le

... Show More
View Publication
Crossref (6)
Crossref
Publication Date
Mon Jun 01 2020
Journal Name
Al-khwarizmi Engineering Journal
Analysis of Different Hand and Finger Grip Patterns using Surface Electromyography and Hand Dynamometry
...Show More Authors

Recording an Electromyogram (EMG) signal is essential for diagnostic procedures like muscle health assessment and motor neurons control. The EMG signals have been used as a source of control for powered prosthetics to support people to accomplish their activities of daily living (ADLs). This work deals with studying different types of hand grips and finding their relationship with EMG activity. Five subjects carried out four functional movements (fine pinch, tripod grip and grip with the middle and thumb finger, as well as the power grip). Hand dynamometer has been used to record the EMG activity from three muscles namely; Flexor Carpi Radialis (FCR), Flexor Digitorum Superficialis (FDS), and Abductor Pollicis Brevis (ABP) with different

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Buckling and Pre Stressed Dynamics Analysis of Laminated Composite Plate with Different Boundary Conditions
...Show More Authors

Critical buckling and natural frequencies behavior of laminated composite thin plates subjected to in-plane uniform load is obtained using classical laminated plate theory (CLPT). Analytical investigation is presented using Ritz- method for eigenvalue problems of buckling load solutions for laminated symmetric and anti-symmetric, angle and cross ply composite plate with different elastic supports along its edges. Equation of motion of the plate was derived using principle of virtual work and solved using modified Fourier displacement function that satisfies general edge conditions. Various numerical investigation were studied to exhibit a convergence and accuracy of the present solution for considering some design parameters such as edge

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Nov 14 2025
Journal Name
Al–bahith Al–a'alami
Evaluation in the Kurdish Media Institutions (A Descriptive Study Survey)
...Show More Authors

The importance of evaluation depends on many institutions, whether governmental or private, including media institutions, rely on the list to evaluate the weight of things and appreciation, as well as judging things, achievements, and everything related to the institution is concerned. Because through evaluation, institutions can recognize weaknesses and strengths. It is also an effective tool for management review, through which the institution can review everything related to planning and decision-making, leadership, incentives and other administrative matters.

Therefore, this study attempts to shed light on the evaluation process, its basics and its importance in general and in the Kurdish media institutions as a model in part

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jul 04 2024
Journal Name
Pharmaceutics
Formulation Development of Meloxicam Binary Ethosomal Hydrogel for Topical Delivery: In Vitro and In Vivo Assessment
...Show More Authors

Abstract: The article aimed to formulate an MLX binary ethosome hydrogel for topical delivery to escalate MLX solubility, facilitate dermal permeation, avoid systemic adverse events, and compare the permeation flux and efficacy with the classical type. MLX ethosomes were prepared using the hot method according to the Box–Behnken experimental design. The formulation was implemented according to 16 design formulas with four center points. Independent variables were (soya lecithin, ethanol, and propylene glycol concentrations) and dependent variables (vesicle size, dispersity index, encapsulation efficiency, and zeta potential). The design suggested the optimized formula (MLX−Ethos−OF) with the highest desirability to perform the

... Show More
Preview PDF
Scopus (9)
Scopus
Publication Date
Thu May 31 2012
Journal Name
Journal Of Baghdad College Dentistry
An evaluation of water absorption of Giomer in comparison to other resin-based restorative materials
...Show More Authors

Background: Polymeric composites have been widely used as dental restorative materials. A fundamental knowledge and understanding of the behavior of these materials in the oral cavity is essential to improve their properties and performance. The goal of this study was to measure water sorption of four composite resins containing different filler and resin matrix contents. Materials and method: Resin composite specimens giomer (Beautifil II) Filtek™ P90, Filtek™ Z350 XT, and Tetric N Ceram were prepared in a cylindrical mould of 3mm thickness and 6mm diameter (n=10) and light cured . All specimens placed in silica-gel desiccators at 37˚C for seven days, a constant weight was obtained. All samples were immersed in deionized distill

... Show More
Publication Date
Fri Nov 14 2025
Journal Name
Journal Of Baghdad College Of Dentistry
An Evaluation of Ion Released from Two Brands of Brackets in Three Types of Mouthwashes
...Show More Authors

Background: Mouthwashes used widely as ancillary to mechanical oral hygiene methods. Little information provided about the effect of mouthwashes on ions released from orthodontic brackets. Therefore, the present study has been established to evaluate the effect of different mouthwashes on the corrosion resistance and the biocompatibility of two brands of brackets. Materials and Methods: Eighty premolar stainless steel brackets were used (40 brackets from each brand). They were subdivided into four subgroups (n=10) according to immersion media (deionized distilled water, Corsodyl, Listerine and Silca herb mouthwashes). Each bracket was stored in a closely packed glass tube filled with 15ml of the immersion media and incubated for 45 days at